Natural Gas Dehydration Systems
TEG Gas Dehydration Unit
LINSON OIL supplies project-configured TEG gas dehydration units using triethylene glycol absorption and regeneration circulation. The contactor, glycol circulation and regeneration functions, piping, instruments, controls and package boundary are developed from the gas composition, moisture basis, operating conditions, downstream requirement and project specification.
- Engineering Basis
- Process data, P&ID and technical specification review
- Package Scope
- Absorption, regeneration, controls and skid integration
- Project Support
- Manufacturing, inspection and FAT by project
Customized Supply
Configuration, material selection, instrumentation and auxiliary systems are confirmed against the project basis.
Integrated Package
Designed for equipment supply, skid integration, documentation and site-specific delivery requirements.
Working Principle
Water removal through absorption and controlled regeneration.
Wet natural gas enters the contactor and contacts lean TEG. Water is absorbed from the gas into the glycol phase, while the dehydrated gas leaves for the downstream process. The water-rich glycol is then routed through the project-defined conditioning and regeneration loop before returning to the contactor as lean glycol. Final process design remains subject to confirmed project data.
Wet Gas Feed
Inlet conditions, liquid carryover, contaminants and required pretreatment are reviewed before package selection.
TEG Absorption
Lean glycol contacts the gas in an absorption column designed around the approved process and mechanical basis.
Rich Glycol Handling
Rich glycol can be routed through flash separation, filtration and heat exchange as required by the project scope.
Regeneration & Return
Regenerated lean glycol is cooled, conditioned and circulated back to the contactor under controlled operating logic.
Applications
Dehydration packages for gas handling and processing projects.
TEG dehydration is reviewed as one process option within the wider gas-treatment train. Upstream separation, gas composition, moisture requirement, downstream use, utilities, plot limits and control philosophy can all affect the package configuration.
Gas Gathering
For gathering stations and field facilities where water management supports downstream handling and equipment protection.
Gas Treatment Trains
For integration with separation, sweetening, hydrocarbon recovery, stabilization or other project-specific gas treatment steps.
Pipeline & Downstream Gas Conditioning
For gas streams requiring project-defined moisture control before transport or subsequent processing.
Associated Gas & Field Processing
TEG dehydration can be evaluated within associated-gas and field-processing schemes where the required gas condition supports this treatment route.
TEG Circulation & Regeneration
A circulation loop configured for the actual operating envelope.
The glycol loop is engineered as a connected system rather than a collection of standalone components. Circulation conditions, heat exchange, flash handling, filtration, regeneration duty, controls and utility availability are evaluated during technical clarification.
- 01
Lean Glycol to Contactor
Conditioned lean glycol is delivered to the absorber through a circulation arrangement selected for the confirmed package design.
- 02
Water Absorption from Gas
Gas-liquid contacting supports moisture removal according to the approved process performance basis and operating conditions.
- 03
Rich Glycol Conditioning
Flash separation, filtering, heat exchange and other conditioning functions are included where required by the process design.
- 04
Regeneration and Reuse
The regeneration section removes absorbed water so glycol can return to circulation under the agreed operating and control philosophy.
Major Configuration
Package components selected by project requirements.
The following items represent common package functions. Inclusion, sizing, material, controls, vendor preferences and interface limits are confirmed during technical review.
Absorption Section
Contactor, inlet/outlet interfaces, liquid distribution, level control and applicable internals are configured for the approved process basis.
Contactor · Internals · Mist Elimination · Instruments
Rich Glycol Section
Rich-glycol flash handling, filtration, circulation pumping, heat exchange and piping are included where required by the selected process design.
Flash Handling · Filters · Pumps · Heat Exchange
Regeneration Section
Regeneration, heating, vapor handling, cooling and ancillary functions are selected according to the confirmed regeneration philosophy and utility basis.
Regenerator · Heating · Vapor Handling · Controls
Skid, Control & Utilities
Structural skid, piping, valves, instruments, electrical integration, control panel, insulation, access platform and utility interfaces defined by project scope.
Skid · Piping · PLC / Control · Electrical · Utilities
Engineering Inputs
Better technical inputs lead to a clearer package proposal.
If complete information is not yet available, our engineering team can identify the key clarification points needed before finalizing a technical offer. All performance and equipment selections remain subject to review and confirmation.
Send available project documentsPROCESS
Gas & Liquid Conditions
Gas composition, inlet moisture/water basis, hydrocarbon content, contaminants, liquid carryover and required downstream gas condition.
OPERATING BASIS
Operating & Design Cases
Normal/minimum/maximum gas flow, operating and design pressure/temperature, expected operating variation and shutdown philosophy.
INTERFACES
Scope & Battery Limits
P&ID, equipment list, plot plan, fuel/electrical/cooling utility availability, tie-in points, downstream equipment and customer supply responsibilities.
PROJECT CONTROLS
Materials, Codes & Documentation
Material requirements, corrosion considerations, hazardous-area needs, inspection plan, document requirements and destination conditions.
Manufacturing & FAT
Controlled fabrication from drawings to project inspection.
LINSON OIL supports fabrication, piping and skid integration with inspection points aligned to the agreed project documentation and inspection plan. Customer, EPC and third-party inspection coordination can be arranged according to the confirmed scope.
- Document control: Data sheets, drawings, material records and inspection documentation managed against approved project requirements.
- Fabrication & assembly: Vessel, piping, structural skid, valves, instruments, electrical and control integration coordinated as applicable.
- Inspection & testing: Dimensional checks, applicable testing, functional checks and package review performed according to the agreed inspection basis.
- FAT support: Factory acceptance activities, witness points and records arranged where required by the project specification.
Related Equipment
Compare and connect the equipment around the gas-treatment train.
Related equipment is selected only where it supports the confirmed feed condition, dehydration route and package boundary.
Gas-Liquid Separator
Upstream liquid removal where required by the feed-gas condition.
View Equipment →Filter Separator
Additional filtration and liquid-removal duty where required for inlet conditioning.
View Equipment →Molecular Sieve Gas Dehydration Unit
Alternative dehydration route to compare against the TEG process basis.
View Equipment →Custom Process Skid
Integrated piping, valves, instruments, electrical systems and controls for project-specific package scope.
View Equipment →Related Solutions
TEG dehydration usually supports a wider gas-processing objective.
Solution
Natural Gas Dehydration & Treatment
Compare dehydration routes and coordinate inlet conditioning, contaminants, utilities and downstream gas requirements.
Solution
Associated Gas Recovery & Utilization
Evaluate dehydration where required within the associated-gas treatment and recovery train.
Solution
Condensate Stabilization
Coordinate gas and condensate treatment where dehydration interfaces with the wider process scheme.
Solution
Modular Skid Process Packages
Integrate vessels, piping, instruments, controls and utilities within a defined package boundary.
RFQ & Technical Clarification
Send your available data for a project-based review.
Share your RFQ, P&ID, Data Sheet, gas composition, moisture basis, operating conditions or scope notes. Our team will review the information and clarify the technical basis needed for a project-specific TEG dehydration proposal.
Detailed datasheets, drawings and project-specific technical documents are prepared after the operating conditions, scope of supply and commercial basis have been sufficiently clarified.
Useful documents
- Process flow diagram, P&ID or process description
- Gas composition and moisture-related requirements
- Operating cases, utility information and site conditions
- Required scope, documentation and inspection expectations
[email protected]